Jandy Pool Heater LED Triple Flash Error Code

Updated 2026-08-30 · review status: manual-verified · reviewed by MiniSplitDecoder Editorial Team Last verified: 2026-08-30

Check your model first

  • JXi 200
  • JXi 260
  • JXi 400
  • LXi 250
  • LXi 400
  • JXi 200/260/400 & LXi 250/400

Match the model on your equipment label to the linked manufacturer documentation. The same code can mean different things across model families.

Quick answer

Ignition Lockout Ignition Lockout. Heater has made three unsuccessful attempts to fire and is in a soft lockout condition. Low gas supply, broken igniter, air in gas line, fan issues, gas valve not opening. System will auto-retry after one hour. Check gas supply, verify igniter condition, and ensure gas valve is in the ON position.

Severity: high · DIY difficulty: easy

Safety

Stop at the exterior: power-cycle at the disconnect, clean the filter/basket, and check for obvious water-flow blockage. Pool heaters combine gas piping, 240 V wiring, and (on heat pumps) refrigerant — burner, control-board, and sealed-system work requires a licensed technician. If you smell gas, shut the gas valve and leave the area first.

What LED Triple Flash means

Ignition Lockout Ignition Lockout. Heater has made three unsuccessful attempts to fire and is in a soft lockout condition. Low gas supply, broken igniter, air in gas line, fan issues, gas valve not opening. System will auto-retry after one hour. Check gas supply, verify igniter condition, and ensure gas valve is in the ON position.

Code meaning varies by series

  • JXi 200/260/400 & LXi 250/400: LED triple flash: ignition lockout - heater made three unsuccessful attempts to fire and is in a soft lockout condition (auto-retries after 1 hour).

First checks before service

This page currently documents the safe reset triage. If the code returns, use the linked source manual or a qualified technician for code-specific diagnosis.

  1. 1. One-time fault event (power disturbance or transient sensor reading) common DIY

    Check: Power-cycle at the breaker/disconnect (or unplug for CPAP), restore, and run the system while watching for the code.

    Fix: If the code does not return after a full run cycle, the fault was transient — monitor, no repair needed.

  2. 2. Fault persists after a clean reset occasional pro only

    Check: If the code returns immediately or every session, note the conditions (startup, heating, after rain).

    Fix: A persisting code points at the component the manual assigns to this code — that repair is technician territory.

Commonly searched as: "jandy led triple flash" · "jandy error code led triple flash" · "jandy pool heater led triple flash"

Sources

Related Pool Heater guides

Hayward Pool Heater Error Codes: Safe Checks