Pentair Pool Heater ERR IGN Error Code
Quick answer
Ignition Failure Heater attempted to light 3 times and failed to establish a flame. Blower runs and igniter fires but no combustion occurs. Gas supply off or pressure too low, clogged burner orifice, cracked or fouled igniter, incorrect spark gap, failed gas valve solenoid, air in gas line after service. Verify the manual gas shutoff valve is open (handle parallel to pipe). Confirm other gas appli
Severity: high · DIY difficulty: intermediate
Safety
TBD - must be written per-code before publish
What ERR IGN means
Ignition Failure Heater attempted to light 3 times and failed to establish a flame. Blower runs and igniter fires but no combustion occurs. Gas supply off or pressure too low, clogged burner orifice, cracked or fouled igniter, incorrect spark gap, failed gas valve solenoid, air in gas line after service. Verify the manual gas shutoff valve is open (handle parallel to pipe). Confirm other gas appliances are working. Power-cycle the heater to clear the lockout and allow a fresh retry. If gas is confirmed but ERR IGN persists, a technician must inspect the igniter and gas valve.
Causes, ranked
1. Gas supply off, or insufficient gas pressure/volume common diy-ok
Check:
Fix:
2. Failed igniter occasional pro-only
Check:
Fix:
3. Failed ignition control module occasional pro-only
Check:
Fix:
Parts & supplies for Pentair Pool Heater: filters, control boards, sensors, and common replacement parts.
Sources
- PoolDial error-code reference (manual-backed) — verified 2026-08-29
- Pentair MasterTemp/Max-E-Therm Heater Installation & User's Guide (Section 5 Troubleshooting) — verified 2026-08-29