Philips E-108: What It Means & What to Do
Quick answer
Philips E-108 is a manufacturer-documented CPAP fault. Start with the exterior checks below and follow the user guide for the exact model; do not open the device.
Equipment: CPAP · Fault type: error · Severity: low
What E-108 means
Humidifier disconnected (ERR_HUMIDIFIER_DISCONNECT). Error level: CONTINUE. Clear the error log and test; verify the humidifier is properly seated and connected.
Meaning varies by model or source
- DreamStation: ERR_HUMIDIFIER_DISCONNECT — error level CONTINUE, failed component: N/A. Humidifier disconnected (ERR_HUMIDIFIER_DISCONNECT). Error level: CONTINUE. Clear the error log and test; verify the humidifier is properly seated and connected.
What you can safely check
- Stop therapy and read the complete displayed message before doing anything else.
- Disconnect power using the device power connector or power supply; do not open the enclosure.
- If overheating is implicated, move the device away from heat and allow it to cool before reuse.
- Inspect the external air filter for blockage and replace it only as the user guide directs.
- Inspect the air tubing for blockage, kinks, damage, or water.
- Where relevant, verify that the humidifier tub or side cover is seated correctly and dry.
- Reconnect power and perform ONE restart only when the manufacturer's user guide allows it for that message.
- If the fault returns, therapy is unavailable, or the message is unrecoverable, contact your CPAP equipment provider or authorized service center. Follow your care provider's guidance if therapy cannot be used.
What not to do
- Do not open the enclosure or replace internal electronics, blower hardware, sensors, or boards yourself.
- Do not perform calibration, enter undocumented service menus, bypass safety mechanisms, or change therapy-pressure settings to work around the fault.
Which models are covered?
- Philips Respironics DreamStation family (CPAP/Bi-level/ASV)
- DreamStation
If the message returns
Contact your CPAP equipment provider or authorized service center. If therapy is unavailable, follow the guidance from your care provider rather than improvising a replacement setting.
Sources
- Philips Respironics DreamStation Service & Technical Reference Manual (1117539, Ver. 18), Section 6: Error Codes — manufacturer-service-manual; verified 2026-08-30
- Philips Respironics DreamStation Service & Technical Reference Manual (mirror copy, Section 6: Error Codes) — manufacturer-service-manual; verified 2026-08-30
- Respironics DreamStation Service & Technical Reference Manual - ManualsLib hosting — manufacturer-service-manual; verified 2026-08-30
Related CPAP guides
CPAP High Leak: What to Check · CPAP Machine Error: Safe Checks Before Calling Your Provider