Lennox Mini Split Error Codes

20 codes · search by exact code, symptom, prefix, or model family

Find a code

Showing all 20 codes

Featured codes

  • EC07 — EC07 on Lennox mini splits (3WMC/MWMC indoor units) means the outdoor fan speed is op
  • EC52 — EC52 on Lennox mini splits means the condenser coil temperature sensor T3 is in open
  • EC53 — EC53 on Lennox mini splits means the outdoor ambient temperature sensor T4 is in open
  • EC54 — EC54 on Lennox mini splits means the compressor discharge temperature sensor TP is in
  • EC56 — EC56 on Lennox mini splits means the evaporator coil outlet temperature sensor (T2B,
  • EL01 — EL01 on Lennox mini splits means a communication malfunction between the outdoor unit

Recently updated

  • P7 updated 2026-08-30
  • P3 updated 2026-08-30
  • P2 updated 2026-08-30
  • P1 updated 2026-08-30
  • F6 updated 2026-08-30
  • F5 updated 2026-08-30

Browse by fault family

Model families

Safe checks with an external tool or supply

These pages list the check you can do from outside the unit, with an optional external tool or maintenance supply. None of them repair an internal fault.

  • EC07 — EC07 on Lennox mini splits (3WMC/MWMC indoor units) means the outdoor fan speed is operating outside the norma… external check: No-rinse mini-split coil cleaner

Related troubleshooting guides

Manufacturer manuals

E codes

  • Lennox E1 error code
    On most Lennox mini-split code lists E1 is a high-pressure protection trip - dirty/blocked outdoor coil, poor clearance, or an overcharge pushing high…
  • Lennox E3 error code
    On Lennox mini-split code lists E3 means outdoor coil blockage (with possible low refrigerant from a leak) - clean the outdoor coil and reset once; lo…
  • Lennox E4 error code
    E4 on Lennox mini splits is a temperature sensor error: on single-zone units it is the indoor return-air (T1) sensor; on multi-zone outdoor boards it …
  • Lennox E5 error code
    E5 on Lennox mini splits means different things by series: single-zone units show E5 for an indoor coil (T2) sensor error, while multi-zone outdoor bo…
  • Lennox EC07 error code
    EC07 on Lennox mini splits (3WMC/MWMC indoor units) means the outdoor fan speed is operating outside the normal range - the outdoor DC fan ran below a…
  • Lennox EC51 error code
    EC51 on Lennox mini splits (3WMC indoor units) means an outdoor unit EEPROM parameter error - the outdoor control board's main chip is not receiving v…
  • Lennox EC52 error code
    EC52 on Lennox mini splits means the condenser coil temperature sensor T3 is in open circuit or short circuited - the outdoor coil thermistor circuit …
  • Lennox EC53 error code
    EC53 on Lennox mini splits means the outdoor ambient temperature sensor T4 is in open circuit or short circuited - the outdoor air thermistor circuit …
  • Lennox EC54 error code
    EC54 on Lennox mini splits means the compressor discharge temperature sensor TP is in open circuit or short circuited - the discharge thermistor circu…
  • Lennox EC56 error code
    EC56 on Lennox mini splits means the evaporator coil outlet temperature sensor (T2B, multi-zone free-match indoor units) is in open circuit or short c…
  • Lennox EL01 error code
    EL01 on Lennox mini splits means a communication malfunction between the outdoor unit and the indoor unit(s) - the indoor unit received no feedback fr…

F codes

  • Lennox F0 error code
    F0 on Lennox mini splits (indoor display; outdoor equivalent PC 08) means outdoor compressor current overload sensed - the outdoor current exceeded th…
  • Lennox F2 error code
    F2 on Lennox mini splits (indoor display; outdoor equivalent EC 52) means a faulty outdoor coil temperature sensor T3 - the condenser thermistor circu…
  • Lennox F3 error code
    F3 on Lennox mini splits (indoor display; outdoor equivalent EC 54) means a compressor discharge temperature sensor error - the discharge thermistor (…
  • Lennox F5 error code
    F5 on Lennox mini splits (indoor display; outdoor equivalent EC 07) means an outdoor unit fan speed error - the outdoor fan ran too slow (about 300 RP…
  • Lennox F6 error code
    F6 on Lennox mini splits (indoor display; outdoor equivalent EC 56) means the evaporator coil outlet temperature sensor (T2B) is in open circuit or sh…

P codes

  • Lennox P1 error code
    P1 on Lennox mini splits means high-pressure protection: the high pressure switch opened (trips at 639 PSI, resets at 464 PSI) because of poor outdoor…
  • Lennox P2 error code
    P2 on Lennox mini splits means low-pressure protection: the low pressure switch opened (trips at 20 PSI, resets at 43 PSI) - typically from low refrig…
  • Lennox P3 error code
    P3 on Lennox mini splits means outdoor unit low-temperature lockout: in heating, the outdoor unit locks out when the temperature stays below -13 F (-2…
  • Lennox P7 error code
    P7 on Lennox mini splits means an outdoor integrated power module (IPM) temperature sensor malfunction - the IPM module's temperature feedback circuit…