Quick answer
LG H29 (CH29) means abnormally high inverter compressor current, often from refrigerant overcharge, blocked refrigerant flow, or poor outdoor ventilation. Clear airflow, reset once; if H29 returns, call a licensed technician.
Severity: high · DIY difficulty: easy
Safety
Stop at the breaker power-cycle and any plug-accessible checks (filters, remote settings, visible wiring). The outdoor unit's capacitor holds a lethal charge and the refrigerant circuit is both pressurized and (on R-32 units) flammable — opening panels or servicing the sealed system is licensed-technician work (EPA 608).
What H29 means
H29 (CH29) means compressor current is abnormally high and the compressor has been stopped for protection. SplitAtlas (anchored to LG's support table) lists too much refrigerant charge, obstructed refrigerant flow and improper outdoor ventilation as causes; LG's own US troubleshooting article groups CH29 with CH21/CH23/CH26 as outdoor compressor or circuit-board problems; Snowflake Aircon matches CH29 to compressor/inverter overcurrent rows.
Code meaning varies by series
- SplitAtlas (LG support table, Mega R-32): CH29 = compressor current abnormally high; refrigerant amount/flow and outdoor ventilation causes
- LG US official help library: CH21, CH23, CH26, CH29 and E9 indicate a problem with the outdoor unit compressor or circuit board - reset once, then service
- Snowflake Aircon: CH29 = compressor/inverter overcurrent protection; stop repeated restarts if it returns
First checks before service
1. One-time fault event (power disturbance or transient sensor reading) common DIY
Check: Power-cycle at the breaker/disconnect (or unplug for CPAP), restore, and run the system while watching for the code.
Fix: If the code does not return after a full run cycle, the fault was transient — monitor, no repair needed.
2. Fault persists after a clean reset occasional pro only
Check: If the code returns immediately or every session, note the conditions (startup, heating, after rain).
Fix: A persisting code points at the component the manual assigns to this code — that repair is technician territory.
Related codes
Sources
- SplitAtlas LG CH29 - compressor current abnormally high (LG support table) — verified 2026-08-29
- LG US official help library - CH01/CH02/CH06/CH12/CH21/CH23/CH26/CH29/E9 outdoor compressor or circuit board — verified 2026-08-29
- Snowflake Aircon LG CH29 - compressor overcurrent rows — verified 2026-08-29
Related Mini Split guides
Mini-Split Communication Error: DIY Checks · Mini-Split Flashing Light Decoder: Blink Patterns · Mini-Split Maintenance Checklist: Seasonal DIY Tasks · Mini-Split Not Cooling: Ranked Causes and DIY Checks