Samsung Mini Split C467 Error Code
Check your model first
- SplitAtlas (current R-32 residential mapping per SplitAtlas)
- CONFLICT NOTE
Match the model on your equipment label to the linked manufacturer documentation. The same code can mean different things across model families.
Quick answer
Samsung C467 maps to Compressor wire missing/rotation error in official Samsung service documentation; SplitAtlas reads it as prohibit-operation (heating) - outdoor conditions outside the allowed heating range. Generation-dependent - verify against your model's manual.
Severity: medium · DIY difficulty: easy
Safety
Stop at the breaker power-cycle and any plug-accessible checks (filters, remote settings, visible wiring). The outdoor unit's capacitor holds a lethal charge and the refrigerant circuit is both pressurized and (on R-32 units) flammable — opening panels or servicing the sealed system is licensed-technician work (EPA 608).
What C467 means
C467 is generation-dependent on Samsung RAC mini splits. Official Samsung service documentation maps C467 to Compressor wire missing / rotation error - the inverter cannot detect compressor rotation, typically a compressor wiring connection fault; SplitAtlas, presenting the current R-32 residential mapping, reads C467 as a prohibit-operation condition in HEATING when outdoor conditions are outside the allowed range. The wiring reading is an electrical fault; the prohibit reading is normally protective and self-clearing.
Code meaning varies by series
- SplitAtlas (current R-32 residential mapping per SplitAtlas): Prohibit operation condition error (HEATING) - outdoor conditions outside allowed HEATING range (SplitAtlas)
- CONFLICT NOTE: SplitAtlas presents C467 as a Prohibit operation condition (HEATING) error; official Samsung documents (Avant RAC service manual and WindFree 3.0 installer quick guide) map C467 to Compressor wire missing / rotation error and map prohibit-operation conditions to C440 (heating) and C441 (cooling). Samsung code assignments differ between product generations.
First checks before service
1. One-time fault event (power disturbance or transient sensor reading) common DIY
Check: Power-cycle at the breaker/disconnect (or unplug for CPAP), restore, and run the system while watching for the code.
Fix: If the code does not return after a full run cycle, the fault was transient — monitor, no repair needed.
2. Fault persists after a clean reset occasional pro only
Check: If the code returns immediately or every session, note the conditions (startup, heating, after rain).
Fix: A persisting code points at the component the manual assigns to this code — that repair is technician territory.
Related codes
Samsung C440 · Samsung C441 · Samsung C464
Sources
- Samsung Avant RAC service manual error-code table - C467 = Comp. wire missing / rotation error — verified 2026-08-29
- Samsung WindFree 3.0 (AR+C) Installer Quick Guide DB68-12003A-01 - outdoor 7-seg code table incl. C467 — verified 2026-08-29
- SplitAtlas Samsung C467 error code page — verified 2026-08-29
Related Mini Split guides
Mini-Split Communication Error: DIY Checks · Mini-Split Flashing Light Decoder: Blink Patterns · Mini-Split Maintenance Checklist: Seasonal DIY Tasks · Mini-Split Not Cooling: Ranked Causes and DIY Checks