LG Mini Split H23 Error Code
Check your model first
- LG General Wall Mounted-Inverter Type service manual (via manualsdump)
- SplitAtlas (LG support table, Mega R-32)
- MyPros+ / HVAC Wiz NYC / BC Wide (heat pump rows)
Match the model on your equipment label to the linked manufacturer documentation. The same code can mean different things across model families.
Quick answer
LG H23/CH23 means an outdoor inverter DC-link voltage fault - the DC bus voltage between the rectifier and compressor inverter drifted out of the safe range (usually too low). Reset once at the breaker; also note any flickering home lights or tripped breakers. Inverter-board and supply diagnosis is technician/electrician work, not DIY.
Severity: high · DIY difficulty: easy
Safety
Stop at the breaker power-cycle and any plug-accessible checks (filters, remote settings, visible wiring). The outdoor unit's capacitor holds a lethal charge and the refrigerant circuit is both pressurized and (on R-32 units) flammable — opening panels or servicing the sealed system is licensed-technician work (EPA 608).
What H23 means
H23 (CH23) means an outdoor inverter DC-link voltage abnormality: LG's wall-mounted inverter service manual's troubleshooting section covers CH23 with DC-link voltage checks (about 140 VDC threshold and supply-voltage verification), and LG's support table describes compressor DC-link high/low voltage. Most references read it as DC link LOW voltage caused by undervoltage supply or a failing inverter circuit; a few series rows also list DC-link overvoltage.
Code meaning varies by series
- LG General Wall Mounted-Inverter Type service manual (via manualsdump): CH23 troubleshooting: check DC link voltage and power source - low voltage (~140 VDC) condition
- SplitAtlas (LG support table, Mega R-32): CH23 = outdoor inverter compressor DC-link high/low voltage - supply-voltage problems or internal inverter circuit fault
- MyPros+ / HVAC Wiz NYC / BC Wide (heat pump rows): CH23 = DC link low voltage - internal electrical voltage dropped too low to run the compressor safely; usually power-supply related
First checks before service
1. One-time fault event (power disturbance or transient sensor reading) common DIY
Check: Power-cycle at the breaker/disconnect (or unplug for CPAP), restore, and run the system while watching for the code.
Fix: If the code does not return after a full run cycle, the fault was transient — monitor, no repair needed.
2. Fault persists after a clean reset occasional pro only
Check: If the code returns immediately or every session, note the conditions (startup, heating, after rain).
Fix: A persisting code points at the component the manual assigns to this code — that repair is technician territory.
Related codes
Sources
- LG General Wall Mounted-Inverter Type service manual - CH23/CH28 troubleshooting (DC link volt. / power source checks) — verified 2026-08-29
- SplitAtlas LG CH23 - outdoor inverter compressor DC-link high/low voltage (LG support table) — verified 2026-08-29
- MyPros+ LG CH23 - DC link low voltage protection shutdown — verified 2026-08-29
- HVAC Wiz NYC - LG Error CH 23: DC Link Low Voltage — verified 2026-08-29
- Heat Pump Answers LG mini split codes - CH23 DC link low voltage — verified 2026-08-29
Related Mini Split guides
Mini-Split Communication Error: DIY Checks · Mini-Split Flashing Light Decoder: Blink Patterns · Mini-Split Maintenance Checklist: Seasonal DIY Tasks · Mini-Split Not Cooling: Ranked Causes and DIY Checks