LG Mini Split H27 Error Code
Check your model first
- SplitAtlas (LG support table, Mega R-32)
- Snowflake Aircon / Cool Aircon SG (wall-mounted rows)
- HVAC-Boss (CH27/29 group)
Match the model on your equipment label to the linked manufacturer documentation. The same code can mean different things across model families.
Quick answer
LG H27/CH27 means an inverter PSC/PFC overcurrent fault - the outdoor power-factor-correction or power-stage circuit detected excessive current and shut down. Reset once at the breaker; if H27 returns or the breaker trips, leave the system off. Inverter-board and power-circuit work is technician-only.
Severity: high · DIY difficulty: easy
Safety
Stop at the breaker power-cycle and any plug-accessible checks (filters, remote settings, visible wiring). The outdoor unit's capacitor holds a lethal charge and the refrigerant circuit is both pressurized and (on R-32 units) flammable — opening panels or servicing the sealed system is licensed-technician work (EPA 608).
What H27 means
H27 (CH27) means an inverter PSC (prospective short circuit / power-stage) or PFC (power-factor correction) overcurrent fault: current between the AC input and DC converter circuit exceeded the safe limit. LG's support table (per SplitAtlas) reads 'PSC/PFC overcurrent - overload operation or damaged internal PCB components'; Singapore code references describe 'PSC fault; inverter compressor converter current too high' and 'inverter current irregularity (PSC/reactor circuit fault)'. Generic blogs sometimes generalize it as board-internal or 'compressor virtual current' errors.
Code meaning varies by series
- SplitAtlas (LG support table, Mega R-32): CH27 = PSC/PFC overcurrent - overload operation or damaged internal PCB components
- Snowflake Aircon / Cool Aircon SG (wall-mounted rows): CH27 = PSC fault; inverter compressor converter current too high between AC and DC converter circuit; reactor circuit fault
- HVAC-Boss (CH27/29 group): CH27 = inverter compressor overcurrent related to the DC link / main power circuitry
First checks before service
1. One-time fault event (power disturbance or transient sensor reading) common DIY
Check: Power-cycle at the breaker/disconnect (or unplug for CPAP), restore, and run the system while watching for the code.
Fix: If the code does not return after a full run cycle, the fault was transient — monitor, no repair needed.
2. Fault persists after a clean reset occasional pro only
Check: If the code returns immediately or every session, note the conditions (startup, heating, after rain).
Fix: A persisting code points at the component the manual assigns to this code — that repair is technician territory.
Related codes
Sources
- SplitAtlas LG CH27 - PSC/PFC overcurrent (LG support table) — verified 2026-08-29
- Snowflake Aircon LG CH27 - PSC fault / inverter compressor converter current too high — verified 2026-08-29
- Cool Aircon SG LG error codes - CH27 inverter current irregularity (PSC/reactor circuit fault) — verified 2026-08-29
- LG HVAC Single Split Trouble Shooting CH21 CH26 CH27 CH29 (official LG video guide grouping) — verified 2026-08-29
- HVAC-Boss LG mini split troubleshooting - CH27/29 inverter compressor overcurrent — verified 2026-08-29
Related Mini Split guides
Mini-Split Communication Error: DIY Checks · Mini-Split Flashing Light Decoder: Blink Patterns · Mini-Split Maintenance Checklist: Seasonal DIY Tasks · Mini-Split Not Cooling: Ranked Causes and DIY Checks