How to Reset a Mini-Split After a Power Outage
Quick answer
Turn the unit off with the remote, switch off the outdoor-unit breaker for 5 minutes, then restore power and restart. Most mini splits resume normally after a clean power cycle — but error codes that survive a reset point to a real fault, not a glitch.
Do this first (works for nearly every brand)
If the breaker trips again immediately when you restore power, stop and leave it off — that indicates a short (compressor, board, or wiring) and needs a technician.
- Stop the unit with the remote. Press the ON/OFF button so the indoor unit isn't trying to run while you cut power.
- Switch off the breaker that feeds the outdoor unit. Mini splits feed both indoor and outdoor units from this single breaker — that's why the breaker matters and the remote alone isn't enough.
- Wait a full 5 minutes. The inverter board holds charge in its capacitors; this wait is what actually clears the fault memory on most brands.
- Restore power and turn the unit on. Set a moderate temperature (24°C / 75°F) and watch the display for 10 minutes.
That's the whole procedure. On the majority of units this clears outage-related faults: memory-glitch codes, brief over/under-voltage trips, and stuck communication states.
Brand quirks worth knowing
- Midea / MRCOOL / Senville: these share Midea platform behavior. If the unit has a wired controller, hold the CHECK/ECO button sequence shown in your controller's manual to view stored codes after a reset — an outage often leaves the last fault in memory even though the unit runs.
- Gree / Tosot / Trane-legacy (Gree OEM): power-cycling clears the code display, but Gree boards keep the fault log. If the same code returns within a few days, treat it as an active fault, not an outage symptom.
- LG: after a clean power cycle, a CH error that returns instantly (within seconds of startup) usually indicates a hard fault — CH05/CH10-family communication codes after outages often trace to a grounded or damaged outdoor wiring run that the surge stressed.
- Daikin: the remote sensor check (hold CANCEL or the check button per model) shows stored codes as U4/E5-family history. Daikin units that ran during a brownout commonly log E5 (compressor overload) once and then run fine.
- Fujitsu / Mitsubishi-style rotary dials: no menu reset exists — the 5-minute breaker procedure is the reset.
What a reset will NOT fix
Never reset a unit that shows a refrigerant or pressure code more than once. Repeated restart-into-fault cycles can destroy a compressor that a single service call would have saved.
- Codes that return immediately on power-up (sensor open/short, board memory failures).
- Refrigerant-pressure codes (E5-family on many brands) — these trip because of a real pressure condition, and repeatedly resetting stresses the compressor.
- Burning smell, tripping breaker, or buzzing from the outdoor unit — these are stop-use conditions, not reset conditions.
The honest rule: a reset is a diagnostic, not a repair. One clean reset is informative; three resets in a row is how a small fault becomes a board replacement.
After the reset: watch for these codes
- Communication codes (E6/E7, CH05, EE, EC51-family): the outage may have stressed the inter-unit wiring or a surge damaged a board. Check the units both run before assuming the worst.
- Sensor codes (E1/E2-family): a brownout can corrupt a sensor reading; if the code clears and stays clear for a full day, ignore it.
- EEPROM/memory codes: these indicate board-level damage from the surge — the board usually needs replacement, which is a technician job.
Find your exact code in the brand list, and check the code's page for its verified meaning before buying parts.
Prevent it next time
- A surge protector sized for mini splits (surge-rated at the disconnect box) is cheap insurance — outage-related board damage is one of the most common non-warranty failures.
- If outages are frequent in your area, ask an electrician about a delayed-restart kit — many boards support a 3-minute random-start delay that protects the compressor from short-cycling when power returns.
Error codes related to this guide
Codes that commonly appear after an outage — and that mean the reset did NOT clear the problem:
- Bosch: Bosch E0 · Bosch E1 · Bosch E3 · Bosch E4 · Bosch E5 · Bosch F0 · Bosch F1 · Bosch F2
- Carrier: Carrier EC07 · Carrier EC51 · Carrier EC52 · Carrier EC53 · Carrier EC54 · Carrier EC56 · Carrier H00 · Carrier H03
- Daikin: Daikin E1 · Daikin E3 · Daikin E5 · Daikin E6 · Daikin E7 · Daikin E8 · Daikin E9 · Daikin F3
- Fujitsu: Fujitsu 11.3 · Fujitsu 11.4 · Fujitsu 16.5 · Fujitsu 22.1 · Fujitsu 23.1 · Fujitsu 62.1 · Fujitsu 62.3 · Fujitsu 62.8
- Gree: Gree E1 · Gree E2 · Gree E3 · Gree E4 · Gree E5 · Gree E6 · Gree E8 · Gree F0
- Lennox: Lennox E1 · Lennox E3 · Lennox E4 · Lennox E5 · Lennox EC07 · Lennox EC51 · Lennox EC52 · Lennox EC53
- Lg: Lg E0 · Lg E6 · Lg F4 · Lg H04 · Lg H05 · Lg H07 · Lg H10 · Lg H21
- Midea: Midea EC07 · Midea EC51 · Midea EC52 · Midea EC53 · Midea EC54 · Midea EC56 · Midea EL01 · Midea EL16
- Mr-cool: Mr-cool EC07 · Mr-cool EC51 · Mr-cool EC52 · Mr-cool EC53 · Mr-cool EC54 · Mr-cool EC71 · Mr-cool EC72 · Mr-cool H00
- Pioneer: Pioneer E0 · Pioneer E1 · Pioneer E2 · Pioneer E3 · Pioneer E4 · Pioneer E5 · Pioneer E6 · Pioneer E7
- Samsung: Samsung C101 · Samsung C102 · Samsung C108 · Samsung C121 · Samsung C122 · Samsung C123 · Samsung C140 · Samsung C142
- Senville: Senville EC07 · Senville EC51 · Senville EC52 · Senville EC53 · Senville EC54 · Senville EC56 · Senville EL01
- Trane: Trane 2-TIME BLINK · Trane 3-TIME BLINK · Trane 4-TIME BLINK · Trane 5-TIME BLINK · Trane 6-TIME BLINK · Trane 7-TIME BLINK · Trane UPPER LAMP 0.5-SECOND BLINK
Related guides
Mini-Split Communication Error: DIY Checks · Mini-Split Error Code Prefixes: What E, F, H, P Mean · Mini-Split Flashing Light Decoder: Blink Patterns · Mini-Split Repair or Replacement? A Practical Guide
Sources
- Midea/MRCOOL DLFSHB service manual (reset & fault-log procedures): verified 2026-08-29
- Gree service manuals — fault memory retention behavior: verified 2026-08-29
- LG official support — CH-series communication error procedures: verified 2026-08-29
- Daikin service manuals — E5 compressor overload / stored-code display: verified 2026-08-29